Welcome to Shenzhen Boyi Jingke Technology Co., LTD.!
Mobile Phone: 189 2926 4368
Company Fax: 0769-8110 5398
Email: ranguanghui@boyijingke.com
Address: 12 / F, D2 Building, Technology Innovation Center, Songhu Wisdom Valley, Dongguan City, Guangdong Province
Model ER2-23P output type PNP output detection method: diffuse reflection, detection distance for reflection (determined by fiber type): 200mm for reflection, normal open/normal closed for reflection: 1200mm for reflection, switchable reaction time P-1 is less than 100us, P-2 is less than 200us, protection circuit power polarity reverse protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods available: power supply voltage 12-24DC ± 10%, floating P-P below 10%, output light source red, 4-element LED body consumption current less than 30
Model ER2-18ZW-V Output Type NPN Output Detection Method Diffuse Reflection, Opposite Reflection (determined by fiber type) Detection Distance Standard: Diffuse Reflection 200mm, Opposite Reflection 700mm Long Distance: Diffuse Reflection 300mm, Opposite Reflection 1200mm Output State Normally Open/Normally Closed Switchable Response Time High Speed: Less than 100us Standard: Less than 500us Long Distance: Less than 3ms Protection Circuit Power Polarity Reverse Protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating
Model ER2-18ZWP Output Type PNP Output Detection Method Diffuse Reflection, Opposite Reflection (determined by fiber type) Detection Distance Standard: Diffuse Reflection 200mm, Opposite Reflection 700mm Long Distance: Diffuse Reflection 300mm, Opposite Reflection 1200mm Output State Normally Open/Normally Closed Switchable Response Time High Speed: Less than 100us Standard: Less than 500us Long Distance: Less than 3ms Protection Circuit Power Polarity Reverse Protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating
Model ER2-18ZW Output Type NPN Output Detection Method Diffuse Reflection, Opposite Reflection (determined by fiber type) Detection Distance Standard: Diffuse Reflection 200mm, Opposite Reflection 700mm Long Distance: Diffuse Reflection 300mm, Opposite Reflection 1200mm Output State Normally Open/Normally Closed Switchable Response Time High Speed: Less than 100us Standard: Less than 500us Long Distance: Less than 3ms Protection Circuit Power Polarity Reverse Protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating P
Model ER2-502 Output Type NPN Output Detection Method Light Intensity (can perform area detection and provide automatic sensitivity tracking function) Detection Distance Diffuse Reflection 300mm, Opposite Reflection 1500mm Output State Normally Open/Normally Closed Switch Reaction Time P-1:50us, P-2:100us, P-3:400us, P-4:800us, P-5: 3.2ms, P-6:4.2ms Output Selection Menu Select OUT1OUT2 Panel Select 1-2,1 is Output 2 is Output Settings Switch Delay Function Off Delay, On Delay, Single Time Open Delay Order
Model ER2-22NH Output Type NPN Output Detection Method Diffuse Reflection, Opposite Reflection (determined by fiber type) Detection Distance Diffuse Reflection 300mm, Opposite Reflection 1500mm Output State Normally Open/Normally Closed Switching Reaction Time P-050us, P-1200us, P-2400us, P-3800us, P-44ms Protection Circuit Power Polarity Reverse Protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating P-P below 10% output light source
Model ER2-23H output type NPN output detection method: diffuse reflection, detection distance for reflection (determined by fiber type): 300mm for reflection, normal open/normal closed for reflection: 1500mm for reflection, switchable reaction time: P-050us, P-1200us, P-2400us, P-3800us, P-44ms for protection circuit: polarity reversal protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating P-P below 10%, output light source red
Model ER2-23HP output type PNP output detection method diffuse reflection, detection distance for reflection (determined by fiber type) diffuse reflection 300mm, reflection 1500mm, output state normally open/normally closed switchable reaction time P-050us, P-1200us, P-2400us, P-3800us, P-44ms protection circuit power polarity reverse protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating P-P below 10% output light source
Model ER2-22HP output type PNP output detection method diffuse reflection, detection distance for reflection (determined by fiber type) diffuse reflection 300mm, reflection 1500mm, output state normally open/normally closed switchable reaction time P-050us, P-1200us, P-2400us, P-3800us, P-44ms protection circuit power polarity reverse protection; Output short circuit or overload protection output delay normal output/output extension/delayed output/primary output, four output methods optional power supply voltage 12-24DC ± 10%, floating P-P below 10% output light source